Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Malar J ; 23(1): 38, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38308253

RESUMO

BACKGROUND: It was hypothesized that glucose-6-phosphate dehydrogenase (G6PD) deficiency confers a protective effect against malaria infection, however, safety concerns have been raised regarding haemolytic toxicity caused by radical cure with 8-aminoquinolines in G6PD-deficient individuals. Malaria elimination and control are also complicated by the high prevalence of G6PD deficiency in malaria-endemic areas. Hence, accurate identification of G6PD deficiency is required to identify those who are eligible for malaria treatment using 8-aminoquinolines. METHODS: The prevalence of G6PD deficiency among 408 Thai participants diagnosed with malaria by microscopy (71), and malaria-negative controls (337), was assessed using a phenotypic test based on water-soluble tetrazolium salts. High-resolution melting (HRM) curve analysis was developed from a previous study to enable the detection of 15 common missense, synonymous and intronic G6PD mutations in Asian populations. The identified mutations were subjected to biochemical and structural characterisation to understand the molecular mechanisms underlying enzyme deficiency. RESULTS: Based on phenotypic testing, the prevalence of G6PD deficiency (< 30% activity) was 6.13% (25/408) and intermediate deficiency (30-70% activity) was found in 15.20% (62/408) of participants. Several G6PD genotypes with newly discovered double missense variants were identified by HRM assays, including G6PD Gaohe + Viangchan, G6PD Valladolid + Viangchan and G6PD Canton + Viangchan. A significantly high frequency of synonymous (c.1311C>T) and intronic (c.1365-13T>C and c.486-34delT) mutations was detected with intermediate to normal enzyme activity. The double missense mutations were less catalytically active than their corresponding single missense mutations, resulting in severe enzyme deficiency. While the mutations had a minor effect on binding affinity, structural instability was a key contributor to the enzyme deficiency observed in G6PD-deficient individuals. CONCLUSIONS: With varying degrees of enzyme deficiency, G6PD genotyping can be used as a complement to phenotypic screening to identify those who are eligible for 8-aminoquinolines. The information gained from this study could be useful for management and treatment of malaria, as well as for the prevention of unanticipated reactions to certain medications and foods in the studied population.


Assuntos
Deficiência de Glucosefosfato Desidrogenase , Malária , Humanos , Deficiência de Glucosefosfato Desidrogenase/epidemiologia , Deficiência de Glucosefosfato Desidrogenase/genética , Deficiência de Glucosefosfato Desidrogenase/diagnóstico , Tailândia/epidemiologia , Glucosefosfato Desidrogenase/genética , Glucosefosfato Desidrogenase/análise , Malária/epidemiologia , Aminoquinolinas/efeitos adversos
2.
PLoS One ; 18(11): e0294200, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37967096

RESUMO

Glucose-6-phosphate dehydrogenase (G6PD) deficiency is an X-linked enzymopathy caused by mutations in the G6PD gene. A medical concern associated with G6PD deficiency is acute hemolytic anemia induced by certain foods, drugs, and infections. Although phenotypic tests can correctly identify hemizygous males, as well as homozygous and compound heterozygous females, heterozygous females with a wide range of G6PD activity may be misclassified as normal. This study aimed to develop multiplex high-resolution melting (HRM) analyses to enable the accurate detection of G6PD mutations, especially among females with heterozygous deficiency. Multiplex HRM assays were developed to detect six G6PD variants, i.e., G6PD Gaohe (c.95A>G), G6PD Chinese-4 (c.392G>T), G6PD Mahidol (c.487G>A), G6PD Viangchan (c.871G>A), G6PD Chinese-5 (c.1024C>T), and G6PD Union (c.1360C>T) in two reactions. The assays were validated and then applied to genotype G6PD mutations in 248 Thai females. The sensitivity of the HRM assays developed was 100% [95% confidence interval (CI): 94.40%-100%] with a specificity of 100% (95% CI: 88.78%-100%) for detecting these six mutations. The prevalence of G6PD deficiency was estimated as 3.63% (9/248) for G6PD deficiency and 31.05% (77/248) for intermediate deficiency by phenotypic assay. The developed HRM assays identified three participants with normal enzyme activity as heterozygous for G6PD Viangchan. Interestingly, a deletion in intron 5 nucleotide position 637/638 (c.486-34delT) was also detected by the developed HRM assays. G6PD genotyping revealed a total of 12 G6PD genotypes, with a high prevalence of intronic variants. Our results suggested that HRM analysis-based genotyping is a simple and reliable approach for detecting G6PD mutations, and could be used to prevent the misdiagnosis of heterozygous females by phenotypic assay. This study also sheds light on the possibility of overlooking intronic variants, which could affect G6PD expression and contribute to enzyme deficiency.


Assuntos
Deficiência de Glucosefosfato Desidrogenase , Glucosefosfato Desidrogenase , Feminino , Humanos , Genótipo , Glucosefosfato Desidrogenase/genética , Glucosefosfato Desidrogenase/metabolismo , Deficiência de Glucosefosfato Desidrogenase/epidemiologia , Deficiência de Glucosefosfato Desidrogenase/genética , Deficiência de Glucosefosfato Desidrogenase/diagnóstico , Mutação , População do Sudeste Asiático
3.
Viruses ; 15(4)2023 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-37112887

RESUMO

In Senegal, the burden of dengue is increasing and expanding. As case management and traditional diagnostic techniques can be difficult to implement, rapid diagnostic tests (RDTs) deployed at point of care are ideal for investigating active outbreaks. The aim of this study was to evaluate the diagnostic performance of the Dengue NS1 and Dengue IgM/IgG RDTs on the serum/plasma samples in a laboratory setting and in the field. During laboratory evaluation, performance of the NS1 RDT was assessed using NS1 ELISA as the gold standard. Sensitivity and specificity were 88% [75-95%] and 100% [97-100%], respectively. Performance of the IgM/IG RDT was assessed using the IgM Antibody Capture (MAC) ELISA, indirect IgG, and PRNT as gold standards. The IgM and IgG test lines respectively displayed sensitivities of 94% [83-99%] and 70% [59-79%] and specificities of 91% [84-95%] and 91% [79-98%]. In the field, the Dengue NS1 RDT sensitivity and specificity was 82% [60-95%] and 75% [53-90%], respectively. The IgM and IgG test lines displayed sensitivities of 86% [42-100%] and 78% [64-88%], specificities of 85% [76-92%] and 55% [36-73%], respectively. These results demonstrate that RDTs are ideal for use in a context of high prevalence or outbreak setting and can be implemented in the absence of a confirmatory test for acute and convalescent patients.


Assuntos
Vírus da Dengue , Dengue , Humanos , Dengue/diagnóstico , Dengue/epidemiologia , Testes de Diagnóstico Rápido , Senegal/epidemiologia , Sensibilidade e Especificidade , Imunoglobulina M , Ensaio de Imunoadsorção Enzimática/métodos , Imunoglobulina G , Anticorpos Antivirais , Proteínas não Estruturais Virais
4.
Sci Rep ; 13(1): 3887, 2023 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-36890186

RESUMO

The emergence of severe acute respiratory syndrome 2 (SARS-CoV-2) variants of concern (VOCs), with mutations linked to increased transmissibility, vaccine escape and virulence, has necessitated the widespread genomic surveillance of SARS-CoV-2. This has placed a strain on global sequencing capacity, especially in areas lacking the resources for large scale sequencing activities. Here we have developed three separate multiplex high-resolution melting assays to enable the identification of Alpha, Beta, Delta and Omicron VOCs. The assays were evaluated against whole genome sequencing on upper-respiratory swab samples collected during the Alpha, Delta and Omicron [BA.1] waves of the UK pandemic. The sensitivities of the eight individual primer sets were all 100%, and specificity ranged from 94.6 to 100%. The multiplex HRM assays have potential as a tool for high throughput surveillance of SARS-CoV-2 VOCs, particularly in areas with limited genomics facilities.


Assuntos
COVID-19 , Humanos , SARS-CoV-2/genética , Mutação , Bioensaio , Genômica
5.
PLoS One ; 18(3): e0281925, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36867620

RESUMO

OBJECTIVES: In order to generate independent performance data regarding accuracy of COVID-19 antigen-based rapid diagnostic tests (Ag-RDTs), prospective diagnostic evaluation studies across multiple sites are required to evaluate their performance in different clinical settings. This report describes the clinical evaluation the GENEDIA W COVID-19 Ag Device (Green Cross Medical Science Corp., Chungbuk, Korea) and the ActiveXpress+ COVID-19 Complete Testing Kit (Edinburgh Genetics Ltd, UK), in two testing sites Peru and the United Kingdom. METHODS: Nasopharyngeal swabs collected from 456 symptomatic patients at primary points of care in Lima, Peru and 610 symptomatic participants at a COVID-19 Drive-Through testing site in Liverpool, England were analyzed by Ag-RDT and compared to RT-PCR. Analytical evaluation of both Ag-RDTs was assessed using serial dilutions of direct culture supernatant of a clinical SARS-CoV-2 isolate from the B.1.1.7 lineage. RESULTS: For GENEDIA brand, the values of overall sensitivity and specificity were 60.4% [95% CI 52.4-67.9%], and 99.2% [95% CI 97.6-99.7%] respectively; and for Active Xpress+ the overall values of sensitivity and specificity were 66.2% [95% CI 54.0-76.5%], and 99.6% [95% CI 97.9-99.9%] respectively. The analytical limit of detection was determined at 5.0 x 102 pfu/ml what equals to approximately 1.0 x 104 gcn/ml for both Ag-RDTs. The UK cohort had lower median Ct values compared to that of Peru during both evaluations. When split by Ct, both Ag-RDTs had optimum sensitivities at Ct<20 (in Peru; 95% [95% CI 76.4-99.1%] and 100.0% [95% CI 74.1-100.0%] and in the UK; 59.2% [95% CI 44.2-73.0%] and 100.0% [95% CI 15.8-100.0%], for the GENDIA and the ActiveXpress+, respectively). CONCLUSIONS: Whilst the overall clinical sensitivity of the Genedia did not meet WHO minimum performance requirements for rapid immunoassays in either cohort, the ActiveXpress+ did so for the small UK cohort. This study illustrates comparative performance of Ag-RDTs across two global settings and considers the different approaches in evaluation methods.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Peru , Estudos Prospectivos , Reino Unido , Teste para COVID-19
6.
Malar J ; 22(1): 60, 2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36803858

RESUMO

BACKGROUND: Rapid diagnostic tests (RDTs) are effective tools to diagnose and inform the treatment of malaria in adults and children. The recent development of a highly sensitive rapid diagnostic test (HS-RDT) for Plasmodium falciparum has prompted questions over whether it could improve the diagnosis of malaria in pregnancy and pregnancy outcomes in malaria endemic areas. METHODS: This landscape review collates studies addressing the clinical performance of the HS-RDT. Thirteen studies were identified comparing the HS-RDT and conventional RDT (co-RDT) to molecular methods to detect malaria in pregnancy. Using data from five completed studies, the association of epidemiological and pregnancy-related factors on the sensitivity of HS-RDT, and comparisons with co-RDT were investigated. The studies were conducted in 4 countries over a range of transmission intensities in largely asymptomatic women. RESULTS: Sensitivity of both RDTs varied widely (HS-RDT range 19.6 to 85.7%, co-RDT range 22.8 to 82.8% compared to molecular testing) yet HS-RDT detected individuals with similar parasite densities across all the studies including different geographies and transmission areas [geometric mean parasitaemia around 100 parasites per µL (p/µL)]. HS-RDTs were capable of detecting low-density parasitaemias and in one study detected around 30% of infections with parasite densities of 0-2 p/µL compared to the co-RDT in the same study which detected around 15%. CONCLUSION: The HS-RDT has a slightly higher analytical sensitivity to detect malaria infections in pregnancy than co-RDT but this mostly translates to only fractional and not statistically significant improvement in clinical performance by gravidity, trimester, geography or transmission intensity. The analysis presented here highlights the need for larger and more studies to evaluate incremental improvements in RDTs. The HS-RDT could be used in any situation where co-RDT are currently used for P. falciparum diagnosis, if storage conditions can be adhered to.


Assuntos
Malária Falciparum , Malária , Adulto , Gravidez , Criança , Humanos , Feminino , Plasmodium falciparum , Testes de Diagnóstico Rápido , Sensibilidade e Especificidade , Malária Falciparum/diagnóstico , Malária Falciparum/epidemiologia , Testes Diagnósticos de Rotina/métodos , Antígenos de Protozoários/análise
7.
Antimicrob Resist Infect Control ; 12(1): 14, 2023 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-36814315

RESUMO

OBJECTIVES: Neonatal sepsis, a major cause of death amongst infants in sub-Saharan Africa, is often gut derived. Gut colonisation by Enterobacteriaceae producing extended spectrum beta-lactamase (ESBL) or carbapenemase enzymes can lead to antimicrobial-resistant (AMR) or untreatable infections. We sought to explore the rates of colonisation by ESBL or carbapenemase producers in two neonatal units (NNUs) in West and East Africa. METHODS: Stool and rectal swab samples were taken at multiple timepoints from newborns admitted to the NNUs at the University College Hospital, Ibadan, Nigeria and the Jaramogi Oginga Odinga Teaching and Referral Hospital, Kisumu, western Kenya. Samples were tested for ESBL and carbapenemase genes using a previously validated qPCR assay. Kaplan-Meier survival analysis was used to examine colonisation rates at both sites. RESULTS: In total 119 stool and rectal swab samples were taken from 42 infants admitted to the two NNUs. Colonisation with ESBL (37 infants, 89%) was more common than with carbapenemase producers (26, 62.4%; P = 0.093). Median survival time before colonisation with ESBL organisms was 7 days and with carbapenemase producers 16 days (P = 0.035). The majority of ESBL genes detected belonged to the CTX-M-1 (36/38; 95%), and CTX-M-9 (2/36; 5%) groups, and the most prevalent carbapenemase was blaNDM (27/29, 93%). CONCLUSIONS: Gut colonisation of neonates by AMR organisms was common and occurred rapidly in NNUs in Kenya and Nigeria. Active surveillance of colonisation will improve the understanding of AMR in these settings and guide infection control and antibiotic prescribing practice to improve clinical outcomes.


Assuntos
Infecções por Enterobacteriaceae , Humanos , Recém-Nascido , beta-Lactamases/genética , Infecções por Enterobacteriaceae/epidemiologia , Quênia , Nigéria , Unidades Hospitalares
8.
BMC Infect Dis ; 23(1): 110, 2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36823583

RESUMO

BACKGROUND: Rapid determination of an individual's antibody status can be beneficial in understanding an individual's immune response to SARS-CoV-2 and for initiation of therapies that are only deemed effective in sero-negative individuals. Antibody lateral flow tests (LFTs) have potential to address this need as a rapid, point of care test. METHODS: Here we present a proof-of-concept evaluation of eight LFT brands using sera from 95 vaccinated individuals to determine sensitivity for detecting vaccination generated antibodies. Samples were analysed on eight different brands of antibody LFT and an automated chemiluminescent microparticle immunoassay (CMIA) that identifies anti-spike antibodies which was used as our reference standard. RESULTS: All 95 (100%) participants tested positive for anti-spike antibodies by the chemiluminescent microparticle immunoassay (CMIA) reference standard post-dose two of their SARS-CoV-2 vaccine: BNT162b2 (Pfizer/BioNTech, n = 60), AZD1222 (AstraZeneca, n = 31), mRNA-1273 (Moderna, n = 2) and Undeclared Vaccine Brand (n = 2). Sensitivity increased from dose one to dose two in six out of eight LFTs with three tests achieving 100% sensitivity at dose two in detecting anti-spike antibodies. CONCLUSIONS: These tests are demonstrated to be highly sensitive to detect raised antibody levels in vaccinated individuals. RDTs are low cost and rapid alternatives to ELISA based systems.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Humanos , Vacina BNT162 , ChAdOx1 nCoV-19 , COVID-19/diagnóstico , COVID-19/prevenção & controle , SARS-CoV-2 , Anticorpos Antivirais , Vacinação
9.
PLoS One ; 18(1): e0280908, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36706119

RESUMO

BACKGROUND: The SARS-CoV-2 pandemic has caused an unprecedented strain on healthcare systems worldwide, including the United Kingdom National Health Service (NHS). We conducted an observational cohort study of SARS-CoV-2 infection in frontline healthcare workers (HCW) working in an acute NHS Trust during the first wave of the pandemic, to answer emerging questions surrounding SARS-CoV-2 infection, diagnosis, transmission and control. METHODS: Using self-collected weekly saliva and twice weekly combined oropharyngeal/nasopharyngeal (OP/NP) samples, in addition to self-assessed symptom profiles and isolation behaviours, we retrospectively compared SARS-CoV-2 detection by RT-qPCR of saliva and OP/NP samples. We report the association with contemporaneous symptoms and isolation behaviour. RESULTS: Over a 12-week period from 30th March 2020, 40·0% (n = 34/85, 95% confidence interval 31·3-51·8%) HCW had evidence of SARS-CoV-2 infection by surveillance OP/NP swab and/or saliva sample. Symptoms were reported by 47·1% (n = 40) and self-isolation by 25·9% (n = 22) participants. Only 44.1% (n = 15/34) participants with SARS-CoV-2 infection reported any symptoms within 14 days of a positive result and only 29·4% (n = 10/34) reported self-isolation periods. Overall agreement between paired saliva and OP/NP swabs was 93·4% (n = 211/226 pairs) but rates of positive concordance were low. In paired samples with at least one positive result, 35·0% (n = 7/20) were positive exclusively by OP/NP swab, 40·0% (n = 8/20) exclusively by saliva and in only 25·0% (n = 5/20) were the OP/NP and saliva result both positive. CONCLUSIONS: HCW are a potential source of SARS-CoV-2 transmission in hospitals and symptom screening will identify the minority of infections. Without routine asymptomatic SARS-CoV-2 screening, it is likely that HCW with SARS-CoV-2 infection would continue to attend work. Saliva, in addition to OP/NP swab testing, facilitated ascertainment of symptomatic and asymptomatic SARS-CoV-2 infections. Combined saliva and OP/NP swab sampling would improve detection of SARS-CoV-2 for surveillance and is recommended for a high sensitivity strategy.


Assuntos
COVID-19 , Saliva , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Estudos de Coortes , Estudos Retrospectivos , Medicina Estatal , Pessoal de Saúde , Manejo de Espécimes , Nasofaringe
10.
Microbiol Spectr ; 10(6): e0201222, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36448777

RESUMO

The COVID-19 pandemic has led to the commercialization of many antigen-based rapid diagnostic tests (Ag-RDTs), requiring independent evaluations. This report describes the clinical evaluation of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom. The collected samples (446 nasal swabs from Brazil and 246 nasopharyngeal samples from the UK) were analyzed by the Ag-RDT and compared to reverse transcription-quantitative PCR (RT-qPCR). Analytical evaluation of the Ag-RDT was performed using direct culture supernatants of SARS-CoV-2 strains from the wild-type (B.1), Alpha (B.1.1.7), Delta (B.1.617.2), Gamma (P.1), and Omicron (B.1.1.529) lineages. An overall sensitivity and specificity of 88.2% (95% confidence interval [CI], 81.3 to 93.3) and 100.0% (95% CI, 99.1 to 100.0), respectively, were obtained for the Brazilian and UK cohorts. The analytical limit of detection was determined as 1.0 × 103 PFU/mL (Alpha), 2.5 × 102 PFU/mL (Delta), 2.5 × 103 PFU/mL (Gamma), and 1.0 × 103 PFU/mL (Omicron), giving a viral copy equivalent of approximately 2.1 × 104 copies/mL, 9.0 × 105 copies/mL, 1.7 × 106 copies/mL, and 1.8 × 105 copies/mL for the Ag-RDT, respectively. Overall, while a higher sensitivity was claimed by the manufacturers than that found in this study, this evaluation finds that the Ag-RDT meets the WHO minimum performance requirements for sensitivity and specificity of COVID-19 Ag-RDTs. This study illustrates the comparative performance of the Hotgen Ag-RDT across two global settings and considers the different approaches in evaluation methods. IMPORTANCE Since the beginning of the SARS-CoV-2 pandemic, we have witnessed growing numbers of antigen rapid diagnostic tests (Ag-RDTs) being brought to market. In the United Kingdom, this was somewhat controlled indirectly as the government offered free tests from a small number of companies. However, as this has now ceased, individuals are responsible for their own acquisition of test kits. Similarly in Brazil, as of January 2022, pharmacies and other health care retailers are permitted to sell Ag-RDTs directly to the community. Many of these Ag-RDTs have not been externally evaluated, and results are not readily available to the public. Thus, there is now a need for a transparent evaluation of Ag-RDTs with both analytical and clinical evaluation. We present an independent review of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Brasil , COVID-19/diagnóstico , Pandemias , Reino Unido , Coloide de Ouro
11.
Front Pharmacol ; 13: 1032938, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36339627

RESUMO

Background: Plasmodium vivax remains the malaria species posing a major threat to human health worldwide owing to its relapse mechanism. Currently, the only drugs of choice for radical cure are the 8-aminoquinolines (primaquine and tafenoquine), which are capable of killing hypnozoites and thus preventing P. vivax relapse. However, the therapeutic use of primaquine and tafenoquine is restricted because these drugs can cause hemolysis in individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency. This study aimed to assess and understand the hemolytic risk of using 8-aminoquinolines for radical treatment in a malaria endemic area of Thailand. Methods: The prevalence of G6PD deficiency was determined using a quantitative test in 1,125 individuals. Multiplexed high-resolution meltinging (HRM) assays were developed and applied to detect 12 G6PD mutations. Furthermore, biochemical and structural characterization of G6PD variants was carried out to understand the molecular basis of enzyme deficiency. Results: The prevalence of G6PD deficiency was 6.76% (76/1,125), as assessed by a phenotypic test. Multiplexed HRM assays revealed G6PD Mahidol in 15.04% (77/512) of males and 28.38% (174/613) of females, as well as G6PD Aures in one female. G6PD activity above the 30% cut-off was detected in those carrying G6PD Mahidol, even in hemizygous male individuals. Two variants, G6PD Murcia Oristano and G6PD Songklanagarind + Viangchan, were identified for the first time in Thailand. Biochemical characterization revealed that structural instability is the primary cause of enzyme deficiency in G6PD Aures, G6PD Murcia Oristano, G6PD Songklanagarind + Viangchan, and G6PD Chinese 4 + Viangchan, with double G6PD mutations causing more severe enzyme deficiency. Conclusion: In western Thailand, up to 22% of people may be ineligible for radical cure. Routine qualitative tests may be insufficient for G6PD testing, so quantitative tests should be implemented. G6PD genotyping should also be used to confirm G6PD status, especially in female individuals suspected of having G6PD deficiency. People with double G6PD mutations are more likely to have hemolysis than are those with single G6PD mutations because the double mutations significantly reduce the catalytic activity as well as the structural stability of the protein.

12.
Sci Rep ; 12(1): 18069, 2022 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-36302782

RESUMO

Despite the availability of highly sensitive polymerase chain reaction (PCR)-based methods, the dearth of remotely deployable diagnostic tools circumvents the early and accurate detection of individuals with post-kala-azar dermal leishmaniasis (PKDL). Here, we evaluate a design-locked loop-mediated isothermal amplification (LAMP) assay to diagnose PKDL. A total of 76 snip-skin samples collected from individuals with probable PKDL (clinical presentation and a positive rK39 rapid diagnostic test (RDT)) were assessed by microscopy, qPCR, and LAMP. An equal number of age and sex-matched healthy controls were included to determine the specificity of the LAMP assay. The LAMP assay with a Qiagen DNA extraction (Q-LAMP) showed a promising sensitivity of 72.37% (95% CI: 60.91-82.01%) for identifying the PKDL cases. LAMP assay sensitivity declined when the DNA was extracted using a boil-spin method. Q-qPCR showed 68.42% (56.75-78.61%) sensitivity, comparable to LAMP and with an excellent agreement, whereas the microscopy exhibited a weak sensitivity of 39.47% (28.44-51.35%). When microscopy and/or qPCR were considered the gold standard, Q-LAMP exhibited an elevated sensitivity of 89.7% (95% CI: 78.83-96.11%) for detection of PKDL cases and Bayesian latent class modeling substantiated the excellent sensitivity of the assay. All healthy controls were found to be negative. Notwithstanding the optimum efficiency of the LAMP assay towards the detection of PKDL cases, further optimization of the boil-spin method is warranted to permit remote use of the assay.


Assuntos
Leishmania donovani , Leishmaniose Cutânea , Leishmaniose Visceral , Parasitos , Dermatopatias Parasitárias , Animais , Humanos , Leishmaniose Visceral/diagnóstico , Leishmania donovani/genética , Parasitos/genética , Leishmaniose Cutânea/diagnóstico , Leishmaniose Cutânea/parasitologia , Teorema de Bayes , Reação em Cadeia da Polimerase em Tempo Real
13.
J Appl Microbiol ; 133(5): 3191-3200, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35946113

RESUMO

AIMS: The environment is increasingly recognized as an important reservoir of antimicrobial resistance genes (ARGs), which can be identified using molecular platforms. Yet, environmental surveillance remains an underutilised tool as there is no agreement on the best strategy for sample processing. We aim to develop a low-cost extraction method independent to commercial kits or reagents. METHODS AND RESULTS: We present a novel, magnetic bead-based method for the isolation of ARGs from river water named MagnaExtract. We present this with analytic limit of detection as well as a case study in Southern Malawi. Here we compare the DNA yield from MagnaExtract with commercially available QIAGEN kits and the crude boil and spin method, using a high-resolution melt analysis PCR panel designed for the detection of third-generation cephalosporin and carbapenem-resistant genes from 98 water samples. CONCLUSION: The MagnaExtract method is comparable, and in some instance's superior to commercially available kits for the isolation of ARGs from river water samples. SIGNIFICANCE AND IMPACT OF THE STUDY: The MagnaExtract approach offers a simple, affordable, high yielding extraction method that could be used for the detection of ARGs from river water samples in surveillance campaigns in East Africa.


Assuntos
Antibacterianos , Rios , Antibacterianos/farmacologia , Antibacterianos/análise , Genes Bacterianos/genética , Farmacorresistência Bacteriana/genética , Malaui , Carbapenêmicos , Cefalosporinas , Fenômenos Magnéticos , Água/análise
14.
PLoS Negl Trop Dis ; 16(8): e0010718, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-36040931

RESUMO

People living with HIV (PLHIV) have an increased risk of developing visceral leishmaniasis (VL) and poor outcomes compared to HIV negative individuals. Here, we aim to establish the prevalence and determinants of asymptomatic Leishmania infection (ALI) in a cohort of PLHIV in Bihar, India. We hoped to evaluate optimal diagnostic algorithms to detect ALI in PLHIV. We conducted a cross-sectional survey of PLHIV ≥18 years of age with no history or current diagnosis of VL or post kala-azar dermal leishmaniasis (PKDL) at anti-retroviral therapy centres within VL endemic districts of Bihar. ALI was defined as a positive rK39 enzyme-linked immunosorbent assay (ELISA), rK39 rapid diagnostic test (RDT) and/or quantitative polymerase chain reaction (qPCR). Additionally, the urinary Leishmania antigen ELISA was evaluated. Determinants for ALI were established using logistic regression and agreement between diagnostic tests calculated using Cohen's Kappa. A total of 1,296 PLHIV enrolled in HIV care, 694 (53.6%) of whom were female and a median age of 39 years (interquartile range 33-46), were included in the analysis. Baseline prevalence of ALI was 7.4% (n = 96). All 96 individuals were positive by rK39 ELISA, while 0.5% (n = 6) and 0.4% (n = 5) were positive by qPCR and rK39 RDT, respectively. Negligible or weak agreement was seen between assays. Independent risk factors for ALI were CD4 counts <100 (OR 3.1; 95% CI 1.2-7.6) and CD4 counts 100-199 (OR = 2.1;95% CI:1.1-4.0) compared to CD4 counts ≥300, and a household size ≥5 (OR = 1.9;95% CI:1.1-3.1). A total of 2.2% (n = 28) participants were positive by Leishmania antigen ELISA, detecting 20 additional participants to the asymptomatic cohort. Prevalence of ALI in PLHIV in VL endemic villages in Bihar was relatively high. Using the Leishmania antigen ELISA, prevalence increased to 9.0%. Patients with low CD4 counts and larger household size were found to have significantly higher risk of ALI. Trial Registration: Clinical Trial Registration CTRI/2017/03/008120.


Assuntos
Infecções por HIV , Leishmania donovani , Leishmania , Leishmaniose Visceral , Leishmaniose , Adulto , Infecções Assintomáticas/epidemiologia , Estudos Transversais , Ensaio de Imunoadsorção Enzimática , Feminino , Infecções por HIV/complicações , Infecções por HIV/epidemiologia , Humanos , Índia/epidemiologia , Leishmaniose Visceral/complicações , Leishmaniose Visceral/diagnóstico , Leishmaniose Visceral/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência
15.
PLoS One ; 17(6): e0270715, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35771760

RESUMO

BACKGROUND: Rapid diagnostic tests (RDTs) developed for point of care detection of SARS-CoV-2 antigen are recommended by WHO to use trained health care workers to collect samples. We hypothesised that self-taken samples are non-inferior for use with RDTs to diagnose COVID-19. We designed a prospective diagnostic evaluation comparing self-taken and healthcare worker (HCW)-taken throat/nasal swabs to perform RDTs for SARS-CoV-2, and how these compare to RT-PCR. METHODS: Eligible participants 18 years or older with symptoms of COVID-19. 250 participants recruited at the NHS Test and Trace drive-through community PCR testing site (Liverpool, UK); one withdrew before analysis. Self-administered throat/nasal swab for the Covios® RDT, a trained HCW taken throat/nasal sample for PCR and HCW comparison throat/nasal swab for RDT were collected. RDT results were compared to RT-PCR, as the reference standard, to calculate sensitivity and specificity. FINDINGS: Seventy-five participants (75/249, 30.1%) were positive by RT-PCR. RDTs with self-taken swabs had a sensitivity of 90.5% (67/74, 95% CI: 83.9-97.2), compared to 78.4% (58/74, 95% CI: 69.0-87.8) for HCW-taken swabs (absolute difference 12.2%, 95% CI: 4.7-19.6, p = 0.003). Specificity for self-taken swabs was 99.4% (173/174, 95% CI: 98.3-100.0), versus 98.9% (172/174, 95% CI: 97.3-100.0) for HCW-taken swabs (absolute difference 0.6%, 95% CI: 0.5-1.7, p = 0.317). The PPV of self-taken RDTs (98.5%, 67/68, 95% CI: 95.7-100.0) and HCW-taken RDTs (96.7%, 58/60, 95% CI 92.1-100.0) were not significantly different (p = 0.262). However, the NPV of self-taken swab RDTs was significantly higher (96.1%, 173/180, 95% CI: 93.2-98.9) than HCW-taken RDTs (91.5%, 172/188, 95% CI 87.5-95.5, p = 0.003). INTERPRETATION: In conclusion, self-taken swabs for COVID-19 testing offer an accurate alternative to healthcare worker taken swabs for use with RDTs. Our results demonstrate that, with no training, self-taken throat/nasal samples can be used by lay individuals as part of rapid testing programmes for symptomatic adults. This is especially important where the lack of trained healthcare workers restricts access to testing.


Assuntos
Teste para COVID-19 , COVID-19 , Adulto , COVID-19/diagnóstico , Pessoal de Saúde , Humanos , Estudos Prospectivos , SARS-CoV-2/genética , Sensibilidade e Especificidade
16.
Microb Genom ; 8(4)2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35404783

RESUMO

Resistance to piperacillin/tazobactam (TZP) in Escherichia coli has predominantly been associated with mechanisms that confer resistance to third-generation cephalosporins. Recent reports have identified E. coli strains with phenotypic resistance to piperacillin/tazobactam but susceptibility to third-generation cephalosporins (TZP-R/3GC-S). In this study we sought to determine the genetic diversity of this phenotype in E. coli (n=58) isolated between 2014-2017 at a single tertiary hospital in Liverpool, UK, as well as the associated resistance mechanisms. We compare our findings to a UK-wide collection of invasive E. coli isolates (n=1509) with publicly available phenotypic and genotypic data. These data sets included the TZP-R/3GC-S phenotype (n=68), and piperacillin/tazobactam and third-generation cephalosporin-susceptible (TZP-S/3GC-S, n=1271) phenotypes. The TZP-R/3GC-S phenotype was displayed in a broad range of sequence types, which was mirrored in the same phenotype from the UK-wide collection, and the overall diversity of invasive E. coli isolates. The TZP-R/3GC-S isolates contained a diverse range of plasmids, indicating multiple acquisition events of TZP resistance mechanisms rather than clonal expansion of a particular plasmid or sequence type. The putative resistance mechanisms were equally diverse, including hyperproduction of TEM-1, either via strong promoters or gene amplification, carriage of inhibitor-resistant ß-lactamases, and an S133G blaCTX-M-15 mutation detected for the first time in clinical isolates. Several of these mechanisms were present at a lower abundance in the TZP-S/3GC-S isolates from the UK-wide collection, but without the associated phenotypic resistance to TZP. Eleven (19%) of the isolates had no putative mechanism identified from the genomic data. Our findings highlight the complexity of this cryptic phenotype and the need for continued phenotypic monitoring, as well as further investigation to improve detection and prediction of the TZP-R/3GC-S phenotype from genomic data.


Assuntos
Infecções por Escherichia coli , Sepse , Antibacterianos/farmacologia , Cefalosporinas/farmacologia , Escherichia coli/genética , Infecções por Escherichia coli/epidemiologia , Humanos , Combinação Piperacilina e Tazobactam
17.
PLoS One ; 17(3): e0263627, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35320286

RESUMO

BACKGROUND: Serological testing for SARS-CoV-2 plays an important role for epidemiological studies, in aiding the diagnosis of COVID-19, and assess vaccine responses. Little is known on dynamics of SARS-CoV-2 serology in African settings. Here, we aimed to characterize the longitudinal antibody response profile to SARS-CoV-2 in Ethiopia. METHODS: In this prospective study, a total of 102 PCR-confirmed COVID-19 patients were enrolled. We obtained 802 plasma samples collected serially. SARS-CoV-2 antibodies were determined using four lateral flow immune-assays (LFIAs), and an electrochemiluminescent immunoassay. We determined longitudinal antibody response to SARS-CoV-2 as well as seroconversion dynamics. RESULTS: Serological positivity rate ranged between 12%-91%, depending on timing after symptom onset. There was no difference in positivity rate between severe and non-severe COVID-19 cases. The specificity ranged between 90%-97%. Agreement between different assays ranged between 84%-92%. The estimated positive predictive value (PPV) for IgM or IgG in a scenario with seroprevalence at 5% varies from 33% to 58%. Nonetheless, when the population seroprevalence increases to 25% and 50%, there is a corresponding increases in the estimated PPVs. The estimated negative-predictive value (NPV) in a low seroprevalence scenario (5%) is high (>99%). However, the estimated NPV in a high seroprevalence scenario (50%) for IgM or IgG is reduced significantly to 80% to 85%. Overall, 28/102 (27.5%) seroconverted by one or more assays tested, within a median time of 11 (IQR: 9-15) days post symptom onset. The median seroconversion time among symptomatic cases tended to be shorter when compared to asymptomatic patients [9 (IQR: 6-11) vs. 15 (IQR: 13-21) days; p = 0.002]. Overall, seroconversion reached 100% 5.5 weeks after the onset of symptoms. Notably, of the remaining 74 COVID-19 patients included in the cohort, 64 (62.8%) were positive for antibody at the time of enrollment, and 10 (9.8%) patients failed to mount a detectable antibody response by any of the assays tested during follow-up. CONCLUSIONS: Longitudinal assessment of antibody response in African COVID-19 patients revealed heterogeneous responses. This underscores the need for a comprehensive evaluation of seroassays before implementation. Factors associated with failure to seroconvert needs further research.


Assuntos
Formação de Anticorpos , COVID-19/imunologia , SARS-CoV-2/imunologia , Adulto , Anticorpos Antivirais/imunologia , COVID-19/epidemiologia , Teste Sorológico para COVID-19/métodos , Etiópia/epidemiologia , Feminino , Humanos , Imunoensaio , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Gravidade do Paciente , Estudos Prospectivos , Estudos Soroepidemiológicos
18.
Sci Rep ; 12(1): 3351, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35233014

RESUMO

Severe acute respiratory coronavirus 2 (SARS-CoV-2) has spread globally since its emergence in 2019. Most SARS-CoV-2 infections generate immune responses leading to rising levels of immunoglobulins (Ig) M, A and G which can be detected using diagnostic tests including enzyme-linked immunosorbent assays (ELISA). Whilst implying previous SARS-CoV-2 infection, the detection of Ig by ELISA does not guarantee the presence of neutralising antibodies (NAb) that can prevent the virus infecting cells. Plaque reduction neutralisation tests (PRNT) detect NAb, but are not amenable to mass testing as they take several days and require use of SARS-CoV-2 in high biocontainment laboratories. We evaluated the ability of IgG and IgM ELISAs targeting SARS-CoV-2 spike subunit 1 receptor binding domain (S1-RBD), and spike subunit 2 (S2) and nucleocapsid protein (NP), at predicting the presence and magnitude of NAb determined by PRNT. IgG S2 + NP ELISA was 96.8% [95% CI 83.8-99.9] sensitive and 88.9% [95% CI 51.8-99.7] specific at predicting the presence of NAbs (PRNT80 > 1:40). IgG and IgM S1-RBD ELISAs correlated with PRNT titre, with higher ELISA results increasing the likelihood of a robust neutralising response. The IgM S1-RBD assay can be used as a rapid, high throughput test to approximate the magnitude of NAb titre.


Assuntos
Anticorpos Antivirais/imunologia , COVID-19/imunologia , Imunoglobulina G/imunologia , Imunoglobulina M/imunologia , Testes de Neutralização , SARS-CoV-2/imunologia , Glicoproteína da Espícula de Coronavírus/imunologia , Idoso , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
19.
J Clin Invest ; 132(7)2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35139037

RESUMO

BackgroundAlthough recent epidemiological data suggest that pneumococci may contribute to the risk of SARS-CoV-2 disease, cases of coinfection with Streptococcus pneumoniae in patients with coronavirus disease 2019 (COVID-19) during hospitalization have been reported infrequently. This apparent contradiction may be explained by interactions of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and pneumococci in the upper airway, resulting in the escape of SARS-CoV-2 from protective host immune responses.MethodsHere, we investigated the relationship of these 2 respiratory pathogens in 2 distinct cohorts of health care workers with asymptomatic or mildly symptomatic SARS-CoV-2 infection identified by systematic screening and patients with moderate to severe disease who presented to the hospital. We assessed the effect of coinfection on host antibody, cellular, and inflammatory responses to the virus.ResultsIn both cohorts, pneumococcal colonization was associated with diminished antiviral immune responses, which primarily affected mucosal IgA levels among individuals with mild or asymptomatic infection and cellular memory responses in infected patients.ConclusionOur findings suggest that S. pneumoniae impair host immunity to SARS-CoV-2 and raise the question of whether pneumococcal carriage also enables immune escape of other respiratory viruses and facilitates reinfection.Trial registrationISRCTN89159899 (FASTER study) and ClinicalTrials.gov NCT03502291 (LAIV study).


Assuntos
COVID-19 , SARS-CoV-2 , Pessoal de Saúde , Humanos , Imunidade , Streptococcus pneumoniae
20.
J Infect ; 84(2): e3-e5, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34974058

RESUMO

This study evaluated the validity and utility of antigen-detection rapid diagnostic tests (Ag-RDTs) for SARS-CoV-2 in elite sports. The data on utility, ease of use and application for Ag-RDTs as a new testing format were positive from players and staff. This evaluation was limited by the low prevalence of SARS-CoV-2 circulating within the three squads. This study highlights the need for continued service evaluations for SARS-CoV-2 Ag-RDTs in elite sport settings.


Assuntos
COVID-19 , SARS-CoV-2 , Antígenos Virais , Humanos , Masculino , Pandemias , Rugby , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...